InfoRad

PRODUCT SETUP MODEM LINKS ERROR CODE LIST

InfoRad Wireless Enterprise Setup

Installation

To install InfoRad Wireless software in Windows 95/98/ME/NT4/2000/XP, click on the Start button and select Run. Type in A:SETUP or B:SETUP in the Open: line and click OK. Follow the prompts for installation.

InfoRad Wireless Software needs at least two numbers to send a wireless message, namely, the Receiver ID Number (typically the seven-digit Pager Number) and the Messaging Service Phone Number (typically the Modem Access Number for alphanumeric paging). Your Paging/Wireless Messaging Service should have these numbers for you.


Client Installation

To install InfoRad Wireless Client software in Windows 95/98/ME/NT4/2000/XP, "browse" to the networked drive and directory where the InfoRad Wireless Enterprise Server is installed. There you will see a Setup.exe. Run this Setup from the Client workstation and this will set up the InfoRad Wireless Enterprise Client. Follow the prompts for installation.

Return to top of page


SV Controller Installation

To install InfoRad Wireless Enterprise SV and InfoRad Wireless Watch-IT SV Controllers on Windows NT 4.0/2000/XP, click on the Start button and select Run. Type in A:CNTSETUP or B:CNTSETUP in the Open: line and click OK. Follow the prompts for installation.

Return to top of page


ASCII File Processing

Network Access Rights

For proper operation of InfoRad Wireless Enterprise and InfoRad Wireless Watch-IT ASCII, certain access rights must be properly set.

If there are problems or errors when sending messages, try manually sending a message from the InfoRad Wireless Enterprise Server or from the InfoRad Wireless Watch-IT. If you can successfully send a wireless message from the "server" application, check the access rights for clients to directories and files. Incorrect settings may hinder the processing of wireless receiver message files. If the access rights are correctly set, please call technical support.

Access Rights Settings

Note: Novell rights are shown. If you are using a different network operating system, set the access rights to the equivalent rights on your network. The following are the file access rights required:

Key:

  • R Read
  • W Write
  • C Create File
  • E Erase or Delete File
  • M Modify File
  • F Filescan and Directory Control (i.e., rename a file)

Item Rights
Program Directory RWCEMF
Message Directory RWCEMF

Note: If you installed the message directory on a local hard drive, the access rights are probably set correctly. You will most likely only have to modify access rights if you set up the messaging message directory on a network drive.

Windows Networks

For Windows NT or Windows 95/98 networks, set the access type for file sharing to SHARED with FULL access for the drive and directory that is being shared.

Return to top of page


InfoRad Wireless Dialing

When setting up your InfoRad Wireless Software, be sure to check your Dialing Properties in Microsoft Windows 95/98/NT. Click Start, under Settings click Control Panel, and in Control Panel, double click on Modems. This will bring up your Modems Properties. Inside Modems Properties click on Dialing Properties button. Here you can check your computer's dialing properties for it's modems. Check to see that the information you have there matches (i.e., does the Area Code match your location, do the numbers for Accessing an Outside Line match?).

Return to top of page


Modem Information

(MS Windows NT needs NT Specific drivers for peripherals to function, thus the next tip about modem drivers does not apply to MS Windows NT users.)

To find out the name of the driver you are using for your modem in MS Windows 95/98, exit from Dialing Properties, click on the Diagnostics tab. Highlight the Communications Port that your modem is attached to (please make note of this Com Port, for later use if you wish to test with Hyperterminal). Click on the More Info button. This will test your modem, and will in the dialog box that pops up give you the Identifier of the modem driver. Note this, and this is the driver you will look up for new "builds" or "makes" of at the website of your modem manufacturer. If you are having difficulties connecting to the paging terminal modem, new drivers may help you.

When finished, go ahead and close your Modems Properties and the Control Panel.

Return to top of page


InfoRad Wireless Communications Settings

If you attempt to "Create" a modem init string (using Create in InfoRad Wireless in Setup, Communications, Modem Configuration, "Override System configuration"), and this string does not work, try editing the characters at the end of the string. Here is what you can try if:

Conexant / Conexant chip set modems

When creating an init string for Conexant modems they generally end in these 5 characters:

"S37=0"

We suggest replacing the final 5 characters with a "+MS=B212" for 1200 baud or  "+MS=B103" for 300 baud. 


3 Com/US Robotics (Sportster)/X2/Telepath series modems

When creating an init string for USR modems they generally end in these 5 characters:

"K0&NO"

We suggest replacing the final character 0(zero) with a "2" for 1200 baud or a "1" for 300 baud. "0" allows the modem to negotiate on its own, and allowing the modem to negotiate on its own may not work. Also, when editing the end of the modem init string, sometimes it is necessary to add "&MO" to force asynchronous communication.

Hayes/Hayes Compatible/Rockwell Chip/K..Flex modems

if end of string reads "S37=0" then try "S37=5" for 1200 baud or "S37=3" for 300 baud (regardless if the prior 2 characters were N1)

if end of string reads "N1S37=0" then try "N0S37=5" for 1200 baud or "N0S37=3" for 300 baud

if end of string reads "S37=0+MS=69,1,1200,1200" then try "S37=5+MS=69,0,1200,1200" for 1200 baud or "S37=3+MS=64,0,300,300" for 300 baud (regardless if the prior 2 characters were N1)

if end of string reads "N1S37=0+MS=69,1,1200,1200" then try "N0S37=5+MS=69,0,1200,1200" for 1200 baud or "N0S37=3+MS=64,0,300,300" for 300 baud.

Messaging Service Connection Properties

Setting the Messaging Services to higher baud rates (9600, 19200, 57600, or 115200) and using Error Correction and Data Compression can also help in modem connections.

Version 9.0.0 to 9.1.8 settings are in Edit, Messaging Services, click Change, then click Advanced. Versions 9.5.0 and above are in Edit, Messaging Services, highlight the service's name and then click Edit, then Port Settings.

Return to top of page


Test With HyperTerminal©

If you are having difficulty setting your modem to communicate with the modem at the paging terminal, you can try using HyperTerminal to test your connection. HyperTerminal is a software bundled with MS Windows 95/98/NT found in your Programs either under Accessories in MS Windows 95/NT or in Communications in Windows 98.

When you start HyperTerminal it will first ask for a Name for the connection. Type in "Test" for a name and press Enter. HyperTerminal will then ask for a phone number to make a connection to, and under this option shows your modem. With the down arrow at the Connect Using box, choose the Com Port (MS Windows Communications Port) which your modem is connected to (this you would find out in your Modem Properties). This will then grey-out the other options, click OK. Next it will show your Port Settings. Set the Baud Rate/Bits Per Second to 1200 or 300, the Data Bits to 7, Parity to Even, and the Stop Bits to 1 (these are typical settings for modems at paging terminals). Set the Flow Control to None.

You will then see a blank Text Box you can type in Hayes AT Commands. Type AT and press Enter. You should get an "OK". Type in ATDT and then the modem number you are trying to connect to (the Wireless Service Number). For instance, type ATDT7654321 or if it is a long distance ATDT1,800,7654321 (commas add delay of 2 seconds). If you need to dial out with a number to access an outside line, for example, by dialing a 9 or an 8, then simply type in the 9 or 8 prior to the number. For example, ATDT9,7654321, or ATDT9,1,800,7654321. HyperTerminal will then attempt to make a connection. If it is unable to do so, attempt again but this time when you make a New Connection, do not change the Port Settings (leave them as Default). If you are unable to make a connection then, your modem may not be capable of a reliable, clean connection to the modem at the paging terminal.

Return to top of page

Copyright © 2000 - 2004 InfoRad, Inc. 
All Rights Reserved
Makers of AlphaPage® Wireless Messaging Products since 1985.




 

 

 

 

 

 

 

 

 

 

Copyright © 2000 InfoRad, Inc. All Rights Reserved Makers of AlphaPage® Wireless Messaging Products since 1985.